beautypg.com

13 e & m signaling commands – PLANET VIP-000 User Manual

Page 97

background image

VIP User

’s Manual

Command Line Interface

83

7.13 E & M Signaling Commands

E&M Common Signaling Configuration Commands

The E&M common signaling configuration commands are used to define common parameters used
on all E&M interfaces, regardless of their mode of operation (Wink Start, Delay Start, or Immediate
Start).

set port port em clear_conf_detect

This command is used to set the minimum duration of on-hook response on the M-lead that is re-
quired for clear confirm to be detected.

set port port em clear_conf_detect milliseconds

Syntax description

milliseconds

Time in milliseconds, ranging from 0 to

65535.

Default

5000

set port port em clear_conf_wait_max

This command is used to set the maximum duration to wait for an on-hook response on the M-lead
after going on-hook on the E-lead.

set port port em clear_conf_wait_max milliseconds

Syntax description

milliseconds

Time in milliseconds, ranging from 0 to 65535.

Default

10000

set port port em clear_detect

This command is used to specify the period of time M-lead needs to be on-hook before call clearing
is declared.

set port port em clear_detect milliseconds

Syntax description

milliseconds

Time in milliseconds, ranging from 0 to 65535.

Default

This manual is related to the following products: