13 e & m signaling commands – PLANET VIP-000 User Manual
Page 97
VIP User
’s Manual
Command Line Interface
83
7.13 E & M Signaling Commands
E&M Common Signaling Configuration Commands
The E&M common signaling configuration commands are used to define common parameters used
on all E&M interfaces, regardless of their mode of operation (Wink Start, Delay Start, or Immediate
Start).
set port port em clear_conf_detect
This command is used to set the minimum duration of on-hook response on the M-lead that is re-
quired for clear confirm to be detected.
set port port em clear_conf_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to
65535.
Default
5000
set port port em clear_conf_wait_max
This command is used to set the maximum duration to wait for an on-hook response on the M-lead
after going on-hook on the E-lead.
set port port em clear_conf_wait_max milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
10000
set port port em clear_detect
This command is used to specify the period of time M-lead needs to be on-hook before call clearing
is declared.
set port port em clear_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default