PLANET VIP-000 User Manual
Page 101
VIP User
’s Manual
Command Line Interface
87
200
E&M Delay Start Signaling Configuration Commands
The E&M delay start signaling configuration commands are used to define parameters specific to
E&M delay start interface. These commands apply to E&M Delay Start signaling protocol only.
set port port emd in_delay_max
This command is used to set the maximum duration of the delay signal response to the Seize De-
tect (of incoming calls) on the M-lead.
set port port emd in_delay_max milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
2500
set port port emd in_delay_min
This command is used to set the minimum duration of the delay signal response to the seize detect
(of incoming calls) on the M-lead.
set port port emd in_delay_min milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
200
set port port emd in_digit_ign
This command is used to set the period of time, after completing the delay signal, before the digits
will be accepted on incoming calls.
set port port emd in_digit_ign milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
30