PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation. However, to improve power management
at the PSE, the PD provides a signature about Class level.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.
A PD shall return Class 0 to 4 in accordance with the maximum power draw as specified by
Table 4-16-1.
Class
Usage
Range of maximum power used by the PD
Class Dsecription
0
Default
12.95 watts (or to 15.4 watts for AF mode)
25.5 watts (or to 30.8 watts for AT mode)
Mid power or High power
1
Optional
0.44 to 3.84 watts
Very low power
2
Optional
3.84 to 6.49 watts
Low power
3
Optional
6.49 to 12.95 watts (or to 15.4 watts)
Mid power
4
Optional
12.95 to 25.50 watts (or to 30.8 watts)
High power
Table 4-16-1 Device class
4.16.3 Port Configuration
This section allows the user to inspect and configure the current PoE port settings
; screen in
Figure 4-16-3
appears.
Figure 4-16-3: Power over Ethernet Configuration Screenshot