Working with Read Cache Settings

www.3ware.com

5

2

In the

Unit Policies

section of the Controller Settings page, select the

desired Read Cache setting, as shown in Figure 3.

Intelligent:

Enables both the Basic and Intelligent Read Prefetch (IRP)

caching features.

Basic:

Enables the Basic read caching mode for the unit.

Disabled:

Disables the Read Cache policy for the unit.

Figure 3. Read Cache policy on the Controller Settings page

After you change the selection, the page refreshes, and a message at the
top confirms the change you have made.

To change the Read Cache unit policy In 3BM

1. At the main 3BM screen, select the unit by highlighting it and pressing

Enter

.

An asterisk appears, indicating that the RAID unit is selected.

2

Tab

to the

Maintain Unit

button and press

Enter

.

3

On the pop-up menu, select

Configure

and press

Enter

.

4

In the Configure Disk Array screen,

Tab

to the field

Read Cache

Setting

.

The current setting—Intelligent, Basic, or Disabled—is shown.