Working with Enclosure Alarms

14

9.5.2 Addendum to the 3ware SAS/SATA RAID Software User Guide

Figure 9. Alarm displays as “Activated” when muted

Controlling an Enclosure Alarm In 3DM 2

In 3DM 2, you can turn off an enclosure alarm that has activated, or you can
choose to mute or unmute it.

To mute, unmute, or turn off an enclosure alarm

1. Choose

Monitor > Enclosure Support

from the menu bar in 3DM 2.

The Status column indicates

Alarm Activated

when the alarm has turned

on, as shown in Figure 10.

Figure 10. Enclosure Summary shows Alarm Activated

2

On the Enclosure Summary page, click the blue Enclosure ID link for the
enclosure to go to the Enclosure Details page.