beautypg.com

Additions to the errors and notifications list – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 23

background image

Other Changes in 9.5.2

www.3ware.com

19

Additions to the Errors and Notifications List

The following AENs (Asynchronous Event Notifications) have been added to
support the enclosure audio alarm. You may see these messages appear on the
3DM 2 Alarms page, and when using the CLI command /cx show
alarms

. For a complete list of messages, see Chapter 13, Trouble-shooting,

in the 3ware SAS/SATA RAID Software User Guide, Version 9.5.1.

8047 Enclosure audio alarm activated but mute

Event Type

Error.

Cause

Applies to 9690SA and 9650SE controllers.

The enclosure’s audio alarm has been activated, but the audibility is mute.

Action

Check the events listing for other error conditions that may have triggered the
alarm.

8048 Enclosure audio alarm failed

Event Type

Error.

Cause

Applies to 9690SA and 9650SE controllers.

The enclosure’s audio alarm has malfunctioned and is not operational.

Action

Refer to the documentation for your enclosure.