Retrotec DucTester 200 Series Residential Applications User Manual

Page 72

background image

Page 72 of 91
©Retrotec Inc. 2015

Flow Conversion Table for Duct Test Pressure of 50 Pa

Table 11: Flow in CFM for various fan pressures, Retrotec Model 200 Fans, Duct Test Pressure: 50 Pa (relative to outdoors)

Flow AWAY or TOWARDS operator, both green and yellow tubes connected.

Fan Pressure

(Pa)

Open

Mid

Low

Fan Pressure

(Pa)

Open

Mid

Low

10

100

4.3

96

318

70

16

12

110

4.8

98

321

71

16

14

119

25

5.2

100

325

72

17

16

127

27

5.6

105

333

74

17

18

135

28

6.0

110

341

75

18

20

142

30

6.4

115

349

77

18

22

150

32

6.8

120

356

79

18

24

156

33

7.1

125

364

81

19

26

163

35

7.5

130

371

83

19

28

169

36

7.8

135

378

84

20

30

175

37

8.1

140

385

86

20

32

181

39

8.5

145

392

88

21

34

187

40

8.8

150

399

89

21

36

192

41

9.1

155

406

91

21

38

198

42

9.4

160

413

92

22

40

203

44

10

165

419

94

22

42

208

45

10

170

426

95

23

44

213

46

10

175

432

97

23

46

218

47

10

180

438

98

23

48

223

48

11

185

445

100

24

50

228

49

11

190

451

101

24

52

232

50

11

195

457

103

24

54

237

51

12

200

463

104

25

56

241

52

12

205

468

106

25

58

246

53

12

210

474

107

26

60

250

54

12

215

480

108

26

62

254

55

13

220

486

110

26

64

258

56

13

225

491

111

27

66

262

57

13

230

497

112

27

68

266

58

13

235

502

114

27

70

270

59

13

240

508

115

28

72

274

60

14

245

513

116

28

74

278

61

14

250

519

118

28

76

282

62

14

255

524

119

28

78

286

63

14

260

529

120

29

80

290

63

15

265

534

121

29

82

293

64

15

270

539

123

29

84

297

65

15

275

544

124

30

86

300

66

15

280

549

125

30

88

304

67

15

285

554

126

30

90

307

68

16

290

559

127

31

92

311

68

16

295

564

129

31

94

314

69

16

300

569

130

31