beautypg.com

Locating duct leaks, Set up the gauge to display duct leakage results, Conduct the duct leakage tests – Retrotec DucTester 200 Series Residential Applications User Manual

Page 3

background image

Page 3 of 91
©Retrotec Inc. 2015

2.3

Problems from duct leakage: ................................................................................ 19

3.

Locating Duct Leaks .................................................................................... 20

3.1

Types of duct leakage tests ................................................................................... 20

3.2

What is duct leakage to the outdoors? .................................................................. 20

3.3

What is duct leakage to the indoors? .................................................................... 20

3.4

How much duct leakage is acceptable under existing Codes? ................................ 21

3.5

Set up your DucTester for duct leakage testing ..................................................... 24

3.6

Unpack, connect the gauge to the DucTester ........................................................ 24

3.6.1.

Charge the gauge .................................................................................................. 24

3.6.2.

Make all connections on the gauge and fan ......................................................... 25

3.7

Blue Tube location matters when testing leaky ducts ............................................ 26

3.8

Connect the DucTester to the Duct System ........................................................... 27

3.8.1.

Connect the Flex Duct to return register .............................................................. 27

3.8.2.

OR Connect the Flex Duct to the air handler cabinet ........................................... 28

3.8.3.

OR Connect the Flex Duct to a ceiling level return using a Flow Hood ................ 28

3.9

Prepare the Duct System for a test ........................................................................ 28

3.9.1.

Before beginning the duct leakage test ................................................................ 28

3.10

Install Range Ring on fan....................................................................................... 29

3.11

Select a test direction ........................................................................................... 30

3.11.1.

Setting up for depressurization ............................................................................ 30

3.11.2.

Setting up for pressurization ................................................................................ 30

4.

Set up the gauge to display Duct Leakage Results ....................................... 31

4.1

Mode setup for duct testing in the US ................................................................... 31

4.2

Mode Setup for various standards around the world ............................................. 32

4.3

Setting up the DM32 gauge for Duct Testing ......................................................... 33

4.4

Setting up and using the DM-2 gauge for Duct testing ........................................... 33

5.

Conduct the Duct Leakage tests .................................................................. 35

5.1

Total Duct Leakage ............................................................................................... 35

5.2

Duct Leakage to Outdoors with 2 gauges and 2 fans .............................................. 36

5.2.1.

Method #1: Set both duct and house to -25 Pa (or 25 Pa) .................................. 36

5.2.2.

Method #2: Set duct to house pressure to 0 Pa (using DucTester gauge) .......... 37

5.3

Duct Leakage to Outdoors with 1 gauge and 2 fans ............................................... 38

5.4

Combined Total Duct Leakage and Duct Leakage to Outdoors Method .................. 41