Choose duct test type, Enter the target test pressure, Enter date the test was carried out – Retrotec DucTester 200 Series Residential Applications User Manual

Page 47: Conditioned floor area, Air handler flow

background image

Page 47 of 91
©Retrotec Inc. 2015

“Leakage Area”: square centimeters, or cm

2

7.3 Choose Duct Test type

Click to select the type of test you are performing: a Total Duct Leakage test or a Duct Leakage to
Outdoors test.

The differences between a Total Duct Leakage test and a Duct Leakage to Outdoors test are described in
section 3.1. For the setup of these tests, refer to the illustrations and descriptions in section 5.

7.4 Enter the Target test pressure

Use the dropdown menu to select the pressure at which the duct system was tested, and the pressure
at which the results will be displayed.

Codes or programs usually require this pressure to be 25 Pa, however it may be 50 Pa. See section 3.4
for these requirements.

7.5 Enter date the test was carried out

Enter the test date in the format of YYYY-MM-DD, where YYYY is the year displayed in four digits, MM is
the month displayed in two digits, and DD is the day displayed in two digits.

7.6 Enter specific parameters for the conditions of this test

7.6.1. Conditioned Floor Area

The Conditioned Floor Area is the area that is normally air-conditioned or heated (i.e., inside the building
envelope). Even though supply ducts may not discharge directly into all these spaces, they are
considered “conditioned” if their temperature follows indoor temperature closer than outdoor
temperature. Likewise, if the area is not air-conditioned or heated, it is not considered to be part of the
Conditioned Floor Area.

The area entered is used to calculate the result for “Flow/Area” that will be displayed on the report. The
Duct Leakage Test Report calls this result the “Leakage/Conditioned Floor Area”.

7.6.2. Air Handler Flow

This is the total air flow through the duct system provided by the system air handler.