beautypg.com

Get results directly from the gauge, Connect pressure tubes to gauge, Tap [range/device] to match range on device in use – Retrotec DM32 User Manual

Page 21

background image

Page 21 of 94
©Retrotec Inc. 2014

3. Get Results directly from the gauge

3.1

Connect Speed Control Cable between the

gauge and fan

Refer to section 2.1 which describes the connection ports from the gauge to a
device such as a Retrotec calibrated fan. The connections for pressure tubing
between a DM32 and a device are the same as the connections between a DM-2
gauge and that device.

Refer to Retrotec’s

Manual-Door Fan Operation

for detailed illustrations on these connections, depending

on what kind of test is to be performed.

3.2

Connect pressure tubes to gauge

3.3

Control the test and read Results on the Home screen

Tap

[Range/Device]

to select the Range Configuration in use

If the Range Configurations associated with the Device in use do not appear, tap

[Change

Device]

to change the Device first

Tap

[Settings]

to display gauge settings that can be changed

If the

[Area]

or

[Volume]

key appears, tap to enter a value for conditioned area or volume, which

will be used to compute the result displayed on [Channel B]

Tap

[Set Speed]

to run the fan at a particular speed

Tap

[Set Pressure]

to achieve a particular enclosure pressure

Tap [Channel A] to

Hold

results being displayed

Tap [Channel B] to change the

Result to be displayed

Tap

[@Pressure]

to estimate a [Channel B] Result at the set pressure

To jump to screen illustrations showing how to use each function, click on the hyperlink in the above list.

3.3.1. Tap [Range/Device] to match Range on Device in use

Figure 13: Change Range for selected Device

3.3.2. Tap [Range/Device] [Change Device] to change Device in use