Event Message
Description
Soak fail Z=xx
Zone XX has failed in the soak test
Special KP=y
Special alarm from the from wireless keypad Y
Spkr l.bat rsS=y
Speaker low battery restore from sounder Y
* Spkr low bat S=y
Speaker low battery fault from sounder Y
Start exit P=y
Exit time started in partition Y
* Part:P=y C=zz
Partition Y part set by user ZZ
* Part: P=y KF=zz
Partition Y part set by remote control ZZ
* Tamper I/O Mdl.
Tamper alarm from I/O module
Tamper I/O Mdl.
Tamper alarm restored from I/O module
* Tamper Keypad=y
Tamper alarm from keypad ID=Y
Tamper rs Zn=xx
Tamper alarm restore on zone no. XX
Tamper rst KP=y
Keypad Y tamper restore
* Tamper Sounder=y
Tamper alarm from wireless sounder Y
* Tamper Zone=xx
Tamper alarm from zone no. XX
* Tech alarm Zn=xx
Alarm from zone XX defined as Technical
Tech rstr Zn=xx
Alarm restored from zone XX defined as Technical
Tmp rstr Sounder=y
Tamper alarm restore from wireless sounder Y
UnOmit Box+Bell
Box + Bell reinstated from omit
UnOmit Zone=xx
Zone no. XX is reinstated from omit
Unknown event
Unknown event alert
User login C=xx
User XX has entered into programming mode. User 99 represents
remote programming from the configuration software
* Water Alrm Zn=xx
Flood alarm from zone no. XX
Water rstr Zn=xx
Flood alarm restore on zone no. XX
Z=xx auto bad
Zone self-test failed, zone no. XX
Z=xx auto ok
Zone self-test OK, zone no. XX
Zn=xx Fault
Zone fault event from zone XX
Zn=xx Fault OK
Zone fault event restore from zone XX
* Event message display cannot be suppressed, as specified by EN50131-1-2006.