Chapter 6 - en 50131 compliance, Agility 3 user manual – RISCO Group 5IN2047 Agility3 Full User Manual UK.pdf User Manual
Page 35

Agility 3 User Manual
Page 35
Chapter 6 - EN 50131 Compliance
Compliance Statement
Hereby, RISCO Group declares that the Agility series of central units and accessories are
designed to comply with:
EN50131-1, EN50131-3 Grade 2
EN50130-5 Environmental class II
EN50131-6 Type A
UK: PD 6662:2004, ACPO DD243:2004 (Police)
Possible logical keys calculations:
Logical codes are codes typed in the wireless keypad to allow level 2 (users) and
level 3 (engineer) access
All code lengths are 4 digits long
0-9 can be used for each digit
There are no disallowed codes, all codes from 0001 to 9999 are acceptable
Invalid codes cannot be created since after 4 digits have been typed "Enter" is
automatic. Codes rejection occurs only when trying to create a code that does not
exist.
Possible physical keys calculations:
Physical keys are implemented in the Wireless Remote Controls.
It is assumed only a user can have remote controls, so having a physical key is
considered as access level 2
Each remote control has an identification code of 24 bit, so the number of options is
2^24
For a remote control to operate with the Agility, a "write" process must be made
after which the keypad is registered with the panel.
A valid remote control is one "Learned" by the panel and allows Set/Unset
A non valid remote control is one not "Learned" by the panel and does not allow
Set/Unset