ANOMALY

POSSIBLE CAUSES

SOLUTIONS

No increase in temperature with

stove in operation.

Incorrect combustion setting.

Check recipe.

Boiler/system dirty.

Check and clean the boiler.

Product power insufficient.

Check that the stove is properly sized for

the requirements of the system.

Poor pellets quality.

Use of MCZ pellets.

Condensation in boiler.

Incorrect temperature setting.

Set the stove to a higher temperature.

Insufficient fuel consumption.

Check recipe.

Radiators cold in winter.

Room thermostat (local or remote) set

too low. If remote thermostat, check if it

is defective.

Set the room thermostat at a higher

temperature, if needed replace it (if

remote).

Circulator does not run because blocked.

Free up the circulator by removing the plug

and turning the shaft with a screwdriver.

Circulator does not run.

Check the electrical connections of the

circulator; replace if necessary.

Radiators have air in them.

Bleed the radiators.

Hot water is not provided.

Circulator (pump) blocked.

Free the circulator (pump).