8-SAFETY DEVICES AND ALARMS

ALARM ALERTS

If an operating anomaly occurs, the product enters the shutdown phase due to an alarm and informs the user regarding the type of fault

by means of a 3 digit code that remains displayed on the emergency panel.

The alarm is indicated permanently by the relative three digit code, a flashing red LED that lights up on the emergency panel and an

intermittent buzzer for the first 10 minutes. Read the instructions in the following 2 paragraphs to cancel the alarm status and restore the

normal operating mode of the stove.

The following table describes the possible alarms indicated by the product, associated to the respective code that appears on the

emergency panel and helpful tips to resolve the problem.

MESSAGE ON THE

DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

The fire does not ignite.

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has

no visible deposits or unburnt pellets.

Check whether the ignition plug becomes hot.

Empty and clean the brazier before relighting..

A02

The fire goes off abnormally.

Due to the hopper being empty (no fuel).

A03

The pellet hopper temperature exceeds the

intended safety threshold.

The structure overheats due to reduced heat

dissipation.

The structure is too hot because the product has been

used for too long at the maximum power or due to poor

ventilation or because the air fans are faulty. When

the product is sufficiently cold, press button B on the

control panel to cancel the alarm. Once the alarm has

been cancelled, the appliance can be switched on.

A04

The temperature of the exhaust smoke has

exceeded the preset safety limits.

The appliance switches off automatically. Let the

product cool down for a few minutes and then switch

it on again. Check the smoke expulsion and the type of

pellets used.

A05

Clogged flue-wind-door open.

Check the smoke duct and make sure the door is closed.

A06

The smoke extractor fails to guarantee sufficient

primary air, required for a correct combustion.

Insufficient draught or clogged brazier.

Verify whether the brazier is clogged and clean it, if

necessary.

Check and if necessary clean the smoke duct and air

inlet.

A08

Faulty smoke fan.

Verify whether the smoke fan compartment is clean,

and particularly if it is blocked by dirt. If this does not

suffice, the smoke fan is faulty. Contact an authorised

service centre to have it replaced.

A09

The smoke probe is faulty and does not detect

the exhaust smoke temperature correctly.

Contact an authorised service centre to have the

component replaced.