24

4-INSTALLATION AND ASSEMBLY

HOOD VENTILATION GRILLES

Foreword

Depending on how the product is positioned, one must provide grilles for ventilation.

If inserted in existing cladding, the ventilation grilles on the cladding will be used.

If used as a new installation, the company recommends installing the ventilation grilles as described in the following paragraph.

HOOD VENTILATION GRILLES FOR NEW CLADDING

It is mandatory to install the hood ventilation grilles of the manufacturer or grilles that can guarantee the same functions

and the same air passage section.

The company cannot be held liable for any damage caused to the structure or the electrical components if this precaution

is not complied with.

The structure becomes very hot and it is essential that constant and efficient ventilation is always guaranteed inside the cladding.

This allows to recover part of the structure heat that would otherwise be lost if left inside the cladding, whilst guaranteeing perfect

product operation.

The company supplies the “Blade” nozzle that is to be installed in the upper part of the insert as shown in the figure.

CONVECTION HOT AIR: ONE MUST RELEASE THE

HOT AIR ACCUMULATED INSIDE THE CLADDING.

AIR INFLOW FROM THE ROOM: ALLOWS AIR

RECYCLE. ONE MUST PROVIDE AN OPENING IN

THE LOWER PART OF THE CLADDING TO PROMOTE

CONVECTION.

SUPPLIED “BLADE” GRILLE

CONVECTION HOT AIR

HOT AIR INFLOW FROM THE ROOM