Esc Set

< Impostazione >

21.0°C 21.04

OFF

Mode:AUTO Menu

Temp:22°C Fan:A

Esc Set

< Impostazione >

Esc Set

< Lingua >

Esc ON OK

< Lingua >

47

7 - CONTROL PANEL

Technical Dept. - All rights reserved - Reproduction is prohibited

SETTING THE LANGUAGE

Press the MENU key then scroll with the keys at the bottom on the right or left until SETTINGS appears, press SET and LANGUAGE will

appear, press SET again and set the chosen language.

By convention the days of the week are indicated with abbreviations deriving from the language set on the panel. In the case of English:

MO

Monday

TH

Thursday

SU

Sunday

TU

Tuesday

FR

Friday

WE

Wednesday

SA

Saturday

21.0°C

21.04

OFF

Esc

Set

<

Setting

>

Esc

Set

<

Setting

>

Esc

Set

<

Language

>

Esc

Set

<

Language

>

Mode: AUTO

Menu

Temp: 22°C

Fan: A

RECIPE SELECTION PROCEDURE

On the control panel menu, "Recipe" appears under the settings menu. This function is for increasing or decreasing pellets loading into

the hopper and is represented as follows:

• To increase: +1 +2 +3 that corresponds to 10-20-30% more compared to the standard recipe set by the company.

• To decrease: -1 -2 -3 that corresponds to 10-20-30% less compared to the standard recipe set by the company.

CHIMNEY SWEEP FUNCTION

ATTENTION.

The "Chimney sweep" function is a technical function aimed at a specialised technician for product calibration

(where required by law) therefore the user must absolutely not activate it.

To activate the Chimney Sweep function one must enter in MENU-SETTINGS-CHIMNEY SWEEP (after the °C-°F entry).

Once the function has been activated the stove will work at maximum power (loading, smoke ventilation, room ventilation) without

listening to any modulation/shutdown requests of the external (thermostat, eco-stop, modem, home automation control) and internal

probes. The only limit that must stay active is the safety threshold of 85°C in the boiler, and relative electronic shutdown in the event of

exceeding this parameter.

The test will work until the technician decides to disable the function by pressing esc or the on/off button.

SETTING WATER TEMPERATURE IN BOILER

The stove has already got a series of standard parameter settings which allow it to operate properly (water temperature 65°C). The water

temperature is shown on the control panel display.

If the user wishes to change the parameters relating to the temperature he/she can do so as follows:

T H2O = Maximum temperature of water in boiler. Upon reaching this temperature, the stove will reduce its performance to prevent

overheating.