7 - CONTROL PANEL
The default temperature is 65°C and it can not be set below 50°C or above 80°C.
To adjust it: press any button; press the "menu" button, via the scrolling buttons display the “SET TEMP.H2O” screen; press the “SET” button;
set the desired temperature via the “<>” scrolling buttons; confirm the temperature with the “OK” button.
MANDATORY EXTERNAL ROOM THERMOSTAT (3) OR STORAGE TANK CONNECTION
One must connect the stove to an external thermostat "3" or to a storage tank; in addition one can connect to a home automation control
unit "4". If one wishes to connect the modem one must use clamp "2".
For the connection one must connect the cables to the product board in the positions indicated below.
It is not necessary to activate the room thermostat or storage tank on the control panel as it is set as active by default.
One recommends the installation to be carried out by a specialised technician.
1
COMPUTER CONNECTION (to be carried out by a specialised technician)
2
MODEM CONNECTION
3
EXTERNAL ROOM THERMOSTAT CONTROL UNIT CONNECTION
4
HOME AUTOMATION CONTROL UNIT CONNECTION
5
WIRELESS PROGRAMMABLE THERMOSTAT (OPTIONAL)