8-SAFETY DEVICES AND ALARMS

Technical Dept. - All rights reserved - Reproduction is prohibited

A10

The spark plug is faulty.

Contact an authorised service centre to have the

component replaced.

A11

Pellets supply fault.

Contact an authorised service centre to have the

component replaced.

A14

Faulty air flow rate sensor.

This alarm does not block the system and only a

warning screen is displayed. Contact an authorised

service centre to have the component replaced.

A17

Water temperature excessively high due to:

• Stove at maximum power, radiators closed.

• Oversized system, e.g. small room, high

capacity product

This alarm does not block the system and only a

warning screen is displayed.

Check that all radiators are open, if the alarm persists

contact an authorised assistance centre.

A18

Water tank temperature too high.

This alarm intervenes if the water contained in

the system does not circulate and therefore the

temperature rises.

Check and eventually unseize the pump. Contact a

service centre to have the component replaced if

needed.

SErvice

Routine maintenance alert.

This flashing message upon start-up indicates that the

preset operating hours before maintenance is due have

elapsed and a qualified technician, recommended by

the manufacturer, must be contacted for maintenance

to be performed.

DELETING THE ALARM STATUS

NEVER open the appliance door whilst the stove is either in the initial startup or on its shut down cycle, pellets will

still be smoldering or therefore volatiles may be present.

ATTENTION!

If during operation or initial ignition you encounter smoke spillage in to the room from the appliance or the flue

then please switch off the appliance, ventilate the room and contact the installation / service engineer immediately

If an alarm is triggered, normal product operation is restored by pressing and holding the on/off key. If the cause that triggered the alarm

does not persist, after a brief verification, the product exits the alarm state and can be restarted.