Exiting alarm condition, Shutdown of the stove – MCZ Ego AIR User Manual

Page 51

background image

PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

51

Operation

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

Info ALARM A02
Flame extinction

Esc ALARM A02
Fill pellet tank

MESSAGE ON

DISPLAY

TYPE OF PROBLEM

SOLUTION

SEr

Regular maintenance advice

When the stove is switched on and this message flashes

this means that the preset operating time before

maintance has expired and maintenance is due to be

carried out. Contact a qualified MCZ technician.

4.15.

Exiting alarm condition

In case of an alarm intervening, to restore the normal operation of the

stove press the on/off key for a long time. After a short verification

phase if the cause that caused the alarm does not persist, the stove

leaves the alarm status and it may restart.

4.15.1.

Shutdown of the stove

The following things can cause stove shutdown:

Overheating of the stove body (“A03”)

Overheating of the smoke (“A04”)

During the function of the stove, an uncontrolled air intake

occurred in the combustion chamber or an obstruction in the flue

pipe. (“A05”)


WHAT TO DO:

When the stove is cold: if the message “A03” appears: The structure is

too hot because the product has been operating for too long at

maximum power, or it is poorly ventilated, or the air fans are faulty

When the stove is sufficiently cold, press button B of the control panel

or OFF on the remote control to cancel the alarm A03. Once the alarm

is cancelled it is possible to relight the stove normally.

If the alarm “A04” appears the stove shutdown in automatic, leave it

to cool down for a few minutes and then re-light. Cancel the alarm and

re-light.

If the alarm “A05” appears: it is caused by prolonged opening of the

fire door or by substantial air infiltration (e.g. smoke fan inspection plug

missing). If not caused by these factors control and if necessary clean

the smoke duct and the flue pipe.

Only after the cause of the blockage has been permanently

eliminated can a fresh attempt to relight the stove be made.

Example: Alarm on the display

of the control panel