Operation

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

4.8.1. COMFORT AIR version

In this version, the stoves are equipped with two fans which duct the

hot air at the front and rear. Conventionally, we will refer to “fan 1” as

the one releasing air at the front and to “fan 2” as the one with the

rear outlet. The adjustment of the two fans summarised in the table

below is independent and is set on the control panel.

Type

Fan speed

Fan 1

0

1

2

3

4

5

Fan 2

0

1

2

3

4

5

35 POSSIBLE COMBINATIONS

COMBINATION 0-0 IS NOT PERMITTED

The procedure is similar to the AIR version. Press the bottom right key

(fig. 1), in the second screenshot the bottom left key, corresponding to

the word “Fire” to modify the flame power. Use the bottom right key to

display the last setting entered for the two fans (fig. 3), or hold down

this key (fig. 3) for a few seconds to modify the speed of fan 1 or 2. To

change the speed of the fans (always beginning with Fan 1), press the

key relating to + or – (fig. 4), then confirm by pressing OK (fig. 5) and

move on to the next fan.

The air at the rear (fan “2”) can be released naturally from the outlet E

fitted as standard (see chapter 3.4) or it can be ducted through outlets

or pipes which are available for purchase as accessories (see chapter

3.4).

26° 10.30
ON

Mode:MANU Menu
Fire:3 Fan1:4

Esc OK
- Fan1 +

Mode:MANU Menu
Fire:3 Fan1:4

Esc OK
- Fan1 +

If the control panel keyboard is left unused for 10

seconds, it automatically quits fan adjustment mode

and confirms the last setting made.

If low fan settings are made, the power of the stove

will be automatically limited to avoid the structure

and the air released by the room fans from

overheating.

This manual is related to the following products: