Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
Mode:AUTO Menu
Temp:20° Fan:2
Mode:AUTO Menu
Temp:20° Fan:2
21.0°C 21.04
OFF
4.7.3. Automatic mode
Whereas MANUAL mode lets you simply choose the thermal power
provided with no variation of operation over time, AUTOMATIC mode
lets you set a temperature to be reached in the room. In this operating
mode the stove will automatically vary the thermal power provided so
as to keep the temperature in the room constantly at the set value.
From the first screen with the word OFF, press any key and the screen
with the word MENU will appear.
With the upper left button select the AUTO function (AUTOMATIC
mode). In this mode using the bottom left button it is possible to
adjust the temperature desired in the room.
Upon reaching the desired temperature in the room, the stove will
gradually go to minimum power. If instead the room temperature drops
below the set limit, the stove will gradually come back up to maximum
hearing performance.
The room temperature is highlighted by the control panel using the
reading of the probe placed near the switch of the stove.
4.7.3.1. Room sensor
The room probe (B) is located at the back of the stove; should this be
near the fumes exhaust tube, we recommend to extract the room
probe so that it sticks out by approximately 10 cm. In this way it will
not be affected by the tube's heat and the measured temperature will
be near to that of the room.
It is advisable to do this operation during installation, since before
extracting the probe (B) it is necessary to take off the clamp (C) that
keeps it connected; operation possible by working inside the stove thus
without the sides. To extract the probe (B) it is necessary to unscrew
the protection cap (A) and slowly pull the probe (B). After extracting
the probe (B) sufficiently, close the protection cap (A) again.
ATTENTION! Once the clamp that binds the probe wire
is taken off, avoid it coming into contact with the hot
parts of the stove.
Fig.7 - Room temperature sensor
Automatic mode