4.7.3. Automatic mode

Whereas MANUAL mode lets you simply choose the thermal power

provided with no variation of operation over time, AUTOMATIC mode

lets you set a temperature to be reached in the room. In this operating

mode the stove will automatically vary the thermal power provided so

as to keep the temperature in the room constantly at the set value.

From the first screen with the word OFF, press any key and the screen

with the word MENU will appear.

With the upper left button select the AUTO function (AUTOMATIC

mode). In this mode using the bottom left button it is possible to

adjust the temperature desired in the room.


Upon reaching the desired temperature in the room, the stove will

gradually go to minimum power. If instead the room temperature drops
below the set limit, the stove will gradually come back up to maximum

hearing performance.
The room temperature is highlighted by the control panel using the

reading of the probe placed near the switch of the stove.

4.7.3.1. Room sensor

The room probe (B) is located at the back of the stove; should this be

near the fumes exhaust tube, we recommend to extract the room

probe so that it sticks out by approximately 10 cm. In this way it will

not be affected by the tube's heat and the measured temperature will

be near to that of the room.
It is advisable to do this operation during installation, since before

extracting the probe (B) it is necessary to take off the clamp (C) that

keeps it connected; operation possible by working inside the stove thus

without the sides. To extract the probe (B) it is necessary to unscrew

the protection cap (A) and slowly pull the probe (B). After extracting

the probe (B) sufficiently, close the protection cap (A) again.

ATTENTION! Once the clamp that binds the probe wire

is taken off, avoid it coming into contact with the hot

parts of the stove.

Fig.7 - Room temperature sensor