First lighting, Note on first ignition – MCZ Ego AIR User Manual
Page 34

PELLET STOVES
Chapter 4
INSTALLATION AND USE MANUAL
page
34
Operation
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
B
A
B
4.6.
FIRST LIGHTING
4.6.1. ON/OFF from the control panel or remote
control (if purchased)
To switch the stove on and off, press the key B for 2 seconds on the
control panel or the A button on the remote control (if purchased).
After a start-up phase that lasts about 15 minutes, the stove
will come up to full operating power.
After the stove is shut down by pressing button B on the remote control
or the B button on the control panel, the cooling-off procedure begins.
This includes the interruption of fuel loading, the cleaning of the grate
and the continuation of ventilation until the stove is sufficiently cold.
This phase may last from 20 to 40 minutes depending on how long the
stove was lit for and where it is located.
4.6.2. Note on first ignition
The first attempt at ignition may not be successful,
since the feeder screw is empty and it is not always
able to fill the grate with required amount of pellets
in time to ensure normal ignition
CANCEL THE ALARM CONDITION FROM THE
CONTROL PANEL (see paragraph 4.14)., REMOVE
PELLETS IN THE GRATE AND REPEAT LIGHTING
After repeated attempts at lighting, if there is no flame even though
pellets are flowing normally, check that the grate is correctly positioned.
It must be placed where it adheres perfectly to its housing and
free of any ash incrustations. If after this check no abnormalities
are found, it means that there may be a problem with the stove
components or that installation may not have been carried out correctly.
REMOVE THE PELLETS FROM THE BURNER AND