4.6.

FIRST LIGHTING

4.6.1. ON/OFF from the control panel or remote
control (if purchased)

To switch the stove on and off, press the key B for 2 seconds on the

control panel or the A button on the remote control (if purchased).
After a start-up phase that lasts about 15 minutes, the stove

will come up to full operating power.

After the stove is shut down by pressing button B on the remote control

or the B button on the control panel, the cooling-off procedure begins.

This includes the interruption of fuel loading, the cleaning of the grate
and the continuation of ventilation until the stove is sufficiently cold.

This phase may last from 20 to 40 minutes depending on how long the

stove was lit for and where it is located.

4.6.2. Note on first ignition

The first attempt at ignition may not be successful,

since the feeder screw is empty and it is not always

able to fill the grate with required amount of pellets

in time to ensure normal ignition

CANCEL THE ALARM CONDITION FROM THE

CONTROL PANEL (see paragraph 4.14)., REMOVE

PELLETS IN THE GRATE AND REPEAT LIGHTING

After repeated attempts at lighting, if there is no flame even though

pellets are flowing normally, check that the grate is correctly positioned.

It must be placed where it adheres perfectly to its housing and

free of any ash incrustations. If after this check no abnormalities

are found, it means that there may be a problem with the stove

components or that installation may not have been carried out correctly.

REMOVE THE PELLETS FROM THE BURNER AND

CONTACT AN AUTHORISED MCZ TECHNICIAN.