beautypg.com

Mounting / start-up safety / mounting, Installation, Start-up – Powerfix Motion Sensor User Manual

Page 39: Setting the detection range (ill. d)

background image

39

GB/MT

Mounting / Start-up

Safety / Mounting

– the motion detector is not installed where there are

strong temperature fluctuations, e.g. due to heating
devices or air conditioners.

Installation

DANGER TO LIFE BY ELECTRIC

SHOCK! Before installation, switch off the electrical
circuit at the circuit breaker box or remove the fuse
from the fuse box.
Note: The recommended installation height is be-
tween 1.8 and 2.5 m.
Note: Before installation, ensure an optimal direc-
tion of motion. The motion detector reacts more sensi-
tively to movement from the side than to motion from
the front (see Ill. A). Therefore, we recommend install-
ing the motion detector

1

to the side of the direc-

tion of movement.
Note: To attach the base plate

4

it is necessary to

drill two holes. We recommend a drill with a 6 mm
diameter.

Remove the screws

2

from the cover of the connec-

tion area by screwing them in the

direction of

rotation (see Ill. B).

Insert the cable through the cable opening

5

of the

base plate

4

.

Screw the base plate

4

to the desired position.

Connect the cable to the screw terminal

3

of the

motion detector as depicted in Ill. C.

Attach the cover of the connection area back to the

base plate

4

by screwing the screws

2

in the

direction of rotation

.

Start-up

Turn the electricity back on. The device is now ready

for use.

Setting the detection range (Ill. D)

Note: the sensor range is max. 12 m (depending on the
surrounding temperature).