The condition data-block, B-67, Esc s – Epson GT-6500 EN User Manual
Page 249: Request condition) command, Scanner model technical data
The Condition Data-Block
The GT-9000 sends the following data-block when it receives the
ESC S
(Request condition) command.
Condition Data-Block
Order of
bytes
Data
(in hex)
Contents
Explanation
(Information block)
1
02
STX code
Header: indicates the beginning of
the data-block
2
xx*
Status
Status byte: indicates the status of
the scanner
3
21
33 Bytes
Byte counter: indicates the number
of bytes of data
4
00
(Data)
1
43
‘‘C’’
Color mode
2
xx*
i
3
52
‘‘R’’
Resolution
4
xx
n1
(main scan resolution)
5
xx
6
xx
n2
(sub scan resolution)
7
xx
8
41
‘‘A’’
Reading area
(main scan offset length)
(sub scan offset length)
(main scan read length)
(sub scan read length)
9
xx
n1
10
xx
11
xx
n2
12
xx
13
xx
n3
14
xx
15
xx
n4
16
xx
17
44
‘‘D’’
Data format
18
xx
i
19
42
‘‘B’’
Halftoning mode
20
xx
i
Scanner Model Technical Data