Contents of the esc f (extended status) data block, Command reference – Epson GT-6500 EN User Manual
Page 105
Contents of the ESC f (extended status) data block
Order of byte
Data (in
hex)
Contents
Explanation
1
02
STX code
Header: indicates the beginning of the
data block
2
xx
Status byte
Byte: indicates the status of the scanner
3
00
33 bytes
Byte counter: indicates the number of
bytes of status data
4
00
5
xx
Scanner status
‘‘1’’ in bit 7 indicates a fatal scanner error
6
xx
ADF status
Bit 7: IST
Bit 6: EN
Bit 5: ERR
Bit 3: PE
Bit 2: PJ
Bit 1: OPN
7
xx
Maximum area
(4 bytes)
Indicates maximum scanning area with
ADF
8
xx
9
xx
10
xx
11
xx
T.P.U.
status
Bit 7: IST
Bit 6: EN
Bit 5: ERR
Bit 1: OPN
12
xx
Maximum area
(4 bytes)
Indicates maximum scanning area with
Transparency Unit
13
xx
14
xx
15
xx
16
−
36
00
Reserved
(22 bytes)
Reserved bytes
IST:
’1’ indicates option is installed
EN:
’1’ indicates option is enabled (otherwise, it is disabled)
ERR:
Logical OR of PE, PJ, and OPN
PE:
’1’ indicates paper empty
PJ:
’1’ indicates paper jam
OPN:
’1’ indicates cover open
Note:
The numerical value of the byte counter consists of two bytes, with the
lower byte preceding the higher byte.
Command Reference