The condition data-block, B-17, Esc s – Epson GT-6500 EN User Manual
Page 199: Request condition) command, Scanner model technical data

Order of
bytes
Data
(in hex)
Contents
Explanation
48
52
‘‘R’’
Available resolution
(400 dpi)
49
90
400
50
01
51
41
‘‘A’’
Maximum reading area at the
maximum resolution and 100%
zoom
(main scan 3424 dots by sub
scan 4640 dots)
52
60
3424
53
0D
54
20
4640
55
12
*(xx denotes a variable)
The Condition Data-Block
The GT-4000 sends the following data-block when it receives the
ESC S
(Request condition) command.
Condition Data-Block
Order of
bytes
Data
(in hex)
Contents
Explanation
(Information block)
1
02
STX code
Header: indicates the beginning of
the data-block
2
xx*
Status
Status byte: indicates the status of
the scanner
3
1D
29 Bytes
Byte counter: indicates the number
of bytes of data
4
00
(Data)
1
43
‘‘C’’
Color mode
2
xx
i
3
52
‘‘R’’
Resolution
4
xx
n1
(main scan resolution)
5
xx
6
xx
n2
(sub scan resolution)
7
xx
8
41
‘‘A’’
Reading area
Scanner Model Technical Data
B-17