Software functions and settings, Software defaults, Scanner model technical data – Epson GT-6500 EN User Manual
Page 185

Software Functions and Settings
The function level of the GT-1000 is B2. The table below lists the
functions and settings that can be controlled with software
commands.
Function
Available settings
Output resolution
3 settings (50, 100, 200 dpi)
Zoom
50% to 200% in 10% increments
Reading area
592
×
840 dots at 200 dpi, 100%
Data format
1 to 8 bits per pixel per color
Color mode
color (page sequence),
monochrome (standard and with dropout color)
Brightness
7 levels
Halftoning mode
3 modes
Gamma correction
5 settings
Software Defaults
With the DIP switches at the preset factory settings, the following
values are the default values on the GT-1000 when the power is
turned on.
Function
Command
Default value
Data format
ESC D
i=01
H
(1 bit/pixel/color)
Resolution
ESC R
n1=100, n2=100 (dpi)
Zoom
ESC H
i1=100, i2=100 (%)
Reading area
ESC A
n1=0, n2=0, n3=296, n4=420 (dot)
Color mode
ESC C
i=00
H
(monochrome)
Brightness
ESC L
BRIGHTNESS dial setting
Gamma correction
ESC Z
i=01
H
(CRT Display A)
Halftoning mode
ESC B
i=00
H
(Halftoning Mode A)
Scanner Model Technical Data
B-3