Prompt screens to be continued, 27) press y button and following screen shows – Sealey VS8622 User Manual
Page 32
- Release brake pedal.
- Checking fill status of wheel brake circuit HZ1 (primary brake
circuit).
25) Press Y button or gently actuate and then release the pedal to
continue, and the device starts to communicate with the vehicle.
26) Use UP/DOWN button to view onscreen prompts
prompt screens to be continued…
........
Inspect Brake Air
.... .
1/3
1. Increase brake
pressure slowly and
evenly.
2. At 10 bar the brake
pedal counterforce
is reduced but
........
Inspect Brake Air
.... .
2/3
needs to be applied
further!
3. Brake pressure must
not rise beyond the
specified range!
4. Actual value should
........
Inspect Brake Air
.... .
3/3
be within the black
range and be held
for 5s.
5. [Y] =Con. [N] =Return
27) Press Y button and following screen shows:
........
Inspect Brake Air
.... .
23.4 bar
0 25
↑
Hold pressure within
black range for 5s.
VS8622_1.03_12/03/09
31