Prompt screen to be continued – Sealey VS8622 User Manual
Page 29
Prompt screen to be continued…
........
Inspect Brake Air
.... .
1/2
1. Brake pressure must
not rise beyond the
specified range!
2. Repeat the process.
3. Press [Y] or
gently actuate and
........
Inspect Brake Air
.... .
2/2
then release the
brake pedal to
continue.
4. [N]= Return.
12) Continue to operate the pedal gently to increase the pressure to
9.5-10.5 bar and keep it for 5s.
........
Inspect Brake Air
.... .
0.1 bar
0 25
↑
Hold pressure within
black range for 5s.
13) Keep operating the pedal to increase the pressure to 19.5-20.5 bar
and hold it for 5s.
14) Follow onscreen instructions to finish current phase of operation:
- Release brake pedal.
- A strong brake pedal kickback indicates a fault.
- Did brake pedal pulse weakly?
- If YES, press [Y] or gently actuate and then release the brake
pedal to continue.
- If NO, press [N].
15) Press Y button or gently actuate and then release the pedal to
continue, and the device starts to communicate with the vehicle.
16) Use UP/DOWN button to view onscreen prompts
VS8622_1.03_12/03/09