System Application Guide

SAG582135000

Spec. No. 582135000 (Model LXP48F1)

Issue AE, January 31, 2007

Page 17 of 43

This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy

Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.

List of Parts

List LX: Distribution Cabinet

(18) Fuse/Circuit Breaker System Positions with
Battery Shunt and Load Shunt

Features

♦ Single Voltage Distribution (-48V)
♦ Maximum Capacity: Input: 500A max.

Total Distribution: 300A max.
Battery Recharge Current: 500A max. @ +50°C; 400A @ +65°C.
Battery Terminals as Remote Feed: 200A max.

♦ (18) Mounting Positions for Load Distribution Fuses or Circuit Breakers, or accepts

Alarm-Type Fuse

Distribution Assembly (Kit P/N 524679)

.

♦ Accepts TPS/TLS-Type Fuses (3 to 100A) or Bullet Nose Type Circuit Breakers (1 to 100A)

Caution: A circuit breaker or fuse with a rating greater than 75 amperes SHALL HAVE an empty

mounting position between it and any other overcurrent protective device.

Caution: The maximum size circuit breaker or fuse used in ambient temperatures above +50°C

ambient shall be 40 amperes.

♦ Includes and (1) Load Shunt (total distribution load) and (1) Battery Shunt
See

Distribution Cabinet Electrical Connection Locations and Dimensions

.

Restrictions

The maximum number of Distribution Cabinets in a system is three (3). Each Distribution Cabinet must be
mounted immediately above a Power Shelf with zero (0) inches of rack space between units to accommodate
the furnished busbar links. Adequate vertical mounting space must be provided above each Distribution
Cabinet to accommodate distribution and battery cabling.

Fuses and/or circuit breakers are to be mounted from right to left, starting with the highest capacity and
working to the lowest capacity.

Maximum size of wire to be connected to a single fuseholder or circuit breaker position is 2 AWG.

Ordering Notes

1) Order circuit breakers, as required, per Table

1

.

2) Order fuses, as required, per Tables

2

.

3) Order one (1) Part No. 117201 fuseholder per fuse ordered in 2) above.

4) Order one (1) Part No. 524690 mounting kit per circuit breaker or fuseholder ordered in 1) or 3) above.

Kit includes bullet socket busbar and hardware for mounting load and return lugs for one distribution
position.

5) Order one (1) Load lug (one-hole, 1/4” bolt clearance hole) and one (1) Load Return lug (two-hole, 1/4”

bolt clearance holes on 5/8” centers) as required for each distribution position per Table

4

.