2 main board, P65) – Epson Stylus TX100 User Manual
Page 65

Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300
Revision A
DISASSEMBLY/ASSEMBLY
Removing the Circuit Boards
65
Confidential
Buttons
1. Remove the Button Power and the Button OP from the Panel Cover.
2. Remove the LED Lens from the Panel Cover.
Figure 4-19. Removing the Buttons
4.4.2 Main Board
Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire (
), Scanner Unit (
), Middle Housing (
Panel Unit (
), Hopper (
)
Removal procedure
1. Remove all the cables and FFCs connected to the Main Board.
Figure 4-20. Removing the Main Board (1)
When installing the Panel Board, align the positioning hole of
the Panel Board with the dowels of the Panel Cover. (See
)
When installing the Panel Unit, align the positioning holes of the
Middle Housing with the dowels of the Panel Cover, then secure
them with four hooks. (See
,
.)
Button Power
Button OP
LED Lens
Panel Cover
Dowel
CN No
Cable
Cable Color
Connector
Color
Pins
J2
Panel FFC
---
Black
10
J3
Power Supply Unit cable
Gray
Brown
3
J4
Scanner FFC
---
Black
12
J5
Scanner Motor Cable
Black,Brown,
Orenge,Yellow
White
4
J6
PF Motor Cable
Red,
Black
White
2
J7
CR Motor Cable
Gray,
Black
Brown
2
J8
Head FFC
---
Black
21
J9
FFC
---
Black
17
Main Board
J3
J6
J7
J2
J4
J5
J8
J9