0 menu map – Magnum Energy ME-ARC Remote User Manual
Page 53
© 2012 Magnum Energy, Inc.
47
4.0 Menu Map
SETUP
continued….
Status/Fault...
03 Charger Setup
03D VAC Dropout
80 VAC / 75 VAC
Ranges: 60-100 VAC, UPS Mode (AC1 only)
Default: 80VAC (AC1); 75VAC (AC2)
Default: 100%
01 Temperatures
Press SELECT
TECH
01 Temperatures
Batt Sensor ##F
01 Temperatures
AGS ##F
01 Temperatures
Transformer ##F
01 Temperatures
Transistors ##F
S
TECH button menu map continues on next page
Read Only displays
02 Revisions
Press SELECT
02 Revisions
Inverter: 0.0
02 Revisions
Remote: 3.0
02 Revisions
AGS: 0.0
02 Revisions
BMK: 0.0
02 Revisions
Router: 0.0
S
Read Only displays
Range: 50-100%
Set VAC Dropout
AC1 = 60 VAC
Set VAC Dropout
AC1 = 80 VAC
Set VAC Dropout
UPS Mode
…
…
Set VAC Dropout
AC2 = 60 VAC
Set VAC Dropout
AC2 = 75 VAC
Set VAC Dropout
AC2 = 100 VAC
…
…
S
S
Status/Fault...
05 BMK Setup
Range: 0.0-25.5 Hrs
Status/Fault...
04 AGS Setup
03F Max Charge
Time = 12.0 Hrs
Set Max Charge
Time = 0.0 Hrs
Set Max Charge
Time = 12.0 Hrs
Set Max Charge
Time = 25.5 Hrs
Default: 12 Hrs
03G Final Charge
Stage = Multi
Set Final Charge
Stage = Multi
Set Final Charge
Stage = Float
Set Final Charge
Stage = Silent
Set DC Volts to
ReBulk = 12.0
Range: Multi, Float, Silent
Default: Multi
Range: 12.0-16.0 VDC (12v)
Default: 12.0 VDC
...
S
S
S
03E Absorb Done
Time = 2.0 Hrs
Set Absorb Done
Time
Set Absorb Done
Amps
Set Absorb Done
SOC
Range: Time, Amps, SOC
Set Absorb Done
Time = 2.0 Hrs
Set Absorb Done
Amps = 20 ADC
Set Absorb Done
SOC = 100%
Default: 20 ADC
Default: 2.0 Hrs
Range: 0.1-25.5 Hrs
Range: 0-150 ADC
S
S
S
S
Refer to AGS SETUP menu maps in
Section 7.0
Refer to BMK SETUP menu maps in
Section 8.0
...
* AC2 only displays on MSH4024RE models.
*
Export Ranges: 110-190 VAC, UPS Mode
Export Default: 150 VAC
Figure 4-4, SETUP/TECH Button Menu Maps