0 setup – Magnum Energy ME-ARC Remote User Manual
Page 17
![background image](https://www.manualsdir.com/files/821297/content/doc017.png)
© 2012 Magnum Energy, Inc.
11
3.0 Setup
Table 3-1, ME-ARC Compatibility Matrix (cont.)
Button
FEATURES/SETTINGS
Model/
Level
Required
Default
Setting
Main
Menu
Menu
Heading/Item
Selections/
A d j u s t m e n t s
Range
METER
03
AGS
Meters
03A AGS Status
Read only display
≥Level 1
Read Only
03B DC Volts-AGS
03C Gen Run Time
03D AGS Temp
03E Since GenRun
04
BMK
Meters
04A BMK Status
Read only display
≥Level 1
Read Only
04B SOC
04C DC Volts-BMK
04D DC Amps-BMK
04E AH in/Out
04F Reset AH Out
04G Total AH Out
04H Minimum
VDC
04I Maximum VDC
SETUP
01 Re-
mote
Setup
01A Set Clock
Time= 12:00A-
12:00P
≥Level 1
12:00A**
01B Contrast
0-100%
100%**
01C Backlight
0-100%
50%**
01D Power Save
OFF, 1-60 Minutes
15 Minute
01E Temp Display
Fahrenheit, Celsius
Fahrenheit
02
Invert
Setup
02A Search Watts
OFF, 5-50 Watts
(1-Watt increments)
≥Level 1
5 Watts
02B LBCO
Setting
9.0-12.2*VDC
≥Level 2
10.0 VDC
02C AC In - Time
Connect Time=
12:00A-12:00P
≥Level 3
[1]
6:00A
6:00P
Disconnect Time=
12:00A-12:00P
02D AC In - VDC
Connect Volts=
9.0-15.9*(12V)
≥Level 3
[1]
11.0
Disconnect Volts=
9.0-15.9*(12V)
14.1