Power ratings, Three-phase 208 vac models z1b1d002 to d046, A.1 power ratings – Yaskawa AC Drive Z1000 Bypass Technical Manual User Manual
Page 296

A.1 Power Ratings
u
Three-Phase 208 Vac Models Z1B1D002 to D046
Table A.1 Power Ratings (Three-Phase 208 V)
Item
Specification
Bypass Model Z1B1
D002
D003
D004
D007
D010
D016
D024
D030
D046
Maximum
Applicable
Motor
Capacity
<1>
HP
0.5
0.75
1
2
3
5
7.5
10
15
kW
0.37
0.55
0.74
1.5
2.2
3.7
5.5
7.5
11
Input
Input Current (A)
<2>
2.9
4.0
5.1
8.0
11.1
17.2
24.7
31.3
46.7
Rated Voltage
Rated Frequency
Three-phase 208 Vac 50/60 Hz
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Output
Rated Output Current (A)
2.4
<3>
3.5
<3>
4.6
<3>
7.5
<3>
10.6
<3>
16.7
<3>
24.2
<3>
30.8
<3>
46.2
<3>
Overload Tolerance
110% of rated output current for 60 s
150% peak
Carrier Frequency
User adjustable between 1 and 12.5 kHz
(Maximum Frequency varies with Rated Output Capacity)
Maximum Output Voltage (V)
Three-phase 208 Vac
Maximum Output Frequency (Hz)
240 Hz
Harmonics
Reduction
DC Link Choke
Built-in
EMC
Filter (IEC/EN 61800-3 Category 2)
Built-in
<1> The motor capacity (HP) refers to an NEC Table 430.250 208 V motor. The rated output current of the drive output amps should be equal to or
greater than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> Carrier frequency is set to 5 kHz. Current derating is required to raise the carrier frequency.
A.1 Power Ratings
296
YASKAWA ELECTRIC SIEP YAIZ1B 01D YASKAWA AC Drive – Z1000 Bypass Technical Manual