Z1000u bypass quick start procedure, Hoa keypad tutorial, Page 11 of 37 – Yaskawa Z1000U HVAC Matrix Bypass User Manual
Page 11: Auto

YASKAWA TOEP YAIZ1D01A Z1000U Matrix Bypass Quick Start Procedure
Z1000U Bypass
Quick Start Procedure
Page 11
of 37
6.1 Review this tutorial to become familiar with HOA Keypad operation before proceeding.
F2
F1
ESC
M
M
AUTO
OFF
ENTER
RESET
ALM
DIGITAL OPERATOR JVOP-183
HAND
F2
F
F2
F2
F2
F2
F2
F2
F2
F2
2
2
F
F
F1
F1
F1
F1
F1
F1
F1
F1
F1
1
A
A
A
A
AU
AU
AU
AU
AU
AU
U
U
U
AU
U
A
O
O
O
O
O
O
O
O
O
O
OF
OF
F
O
F
NTE
ENTE
ENTE
NT
ENTE
NT
NTE
E
E
E
NTE
RE
RE
RE
RE
E
RE
R
RE
S
S
S
S
S
S
S
S
E
E
E
E
E
E
E
E
E
E
E
E
E
E
ET
ET
E
E
E
HAND
HAN
HAN
HAND
AND
AND
AND
N
HAN
ES
ES
ESC
ESC
ESC
ESC
ESC
ESC
ESC
C
C
C
C
12
11
9
8
1
2
3
10
4
5 6
7
No.
Display
Key or Indicator Name
Function
1
Function F1 (RLY)
Selects Drive Test Mode
Note: Applies specifi cally to drives confi gured with 3-contactor. Pressing the
F1 (RLY) key places the drive in Drive Test Mode. Power is applied to the drive
in the bypass mode.
Function F2 (BYP/DRV)
Toggles selection between Bypass Mode and Drive Mode.
2
ESC
•
Returns to the previous display.
•
Moves the cursor one space to the left.
•
In Drive Mode, repeatedly pressing this button will return to the Frequency
Reference display.
•
In Bypass Mode, repeatedly pressing this button will return to the UB-01
“Bypass Current” display.
•
During parameter entry, allows aborting the current edited value and exits
the parameter editing mode.
3
RESET
•
Moves the cursor to the right.
•
Resets the bypass or drive to clear a fault situation
•
Certain drive conditions may require pressing the OFF key before the
RESET key will clear a fault..
4
AUTO
Selects AUTO mode.
5
Up Arrow
Scrolls up to display the next item, selects parameter numbers, and
increments setting values.
6
Down Arrow
Scrolls down to display the previous item, selects parameter numbers, and
decrements setting values.
7
OFF Key
If the drive was operating the motor, the motor will stop according to the
stopping method selected in b1-03. If the bypass was operating the motor, the
bypass contactor opens and the motor coasts to a stop.
8
ENTER
•
Enters parameter values and settings.
•
Selects a menu item to move between displays.
9
HAND
Selects HAND mode.
10
AUTO
AUTO Light
Lit or fl ashing while the drive is in AUTO mode.
11
HAND Light
Lit while the drive is in HAND mode.
12
ALARM Light
•
Flashing: Indicates Alarm (minor fault)
•
Solid: Indicates Fault (major fault)
HOA Keypad Tutorial
6
STEP