MotionSuite™ MP940 Machine Controller Hardware Manual

Section 4: LED Indicators

19

Section 4: LED Indicators

LED Display

The MP940 runs a series of tests during start-up. If an error is detected, the ERR LED
flashes, and the content of the error corresponds to the number of flashes.
MotionSuite™ software tools cannot communicate with the controller while an error
LED is flashing or memory initialization is occurring. The MP940 LEDs are shown in
the following table.

In addition, there are the following four LEDs.

LED Display Patterns

Type

LED

Meaning

RDY

(Green)

RUN

(Green)

ERR

(Red)

BAT

(Red)

Normal

ON

OFF

OFF

OFF

Application program stopped

ON

ON

OFF

OFF

Normal application program execution

Error

OFF

OFF

ON

OFF

Memory error (initialization may be required)

OFF

OFF

OFF

OFF

Initial operation (when display continues)

OFF

OFF

Flashing

OFF

1. 2 flashes: RAM error
2. 3 flashes: ROM error
3. 4 flashes: Peripheral LSI letter

Warning

ON

Battery alarm

ON

ON

ON

OFF

1. Operand error or I/O error

System (S) register message
(no LED display)

Hardware status (Momentary Stop, RUN/STOP, Test-
ing Mode, etc.)

Other

Flashing

Flashing

OFF

OFF

Memory initialization by DIP switch setting complete.

OFF

OFF

ON

OFF

Offline testing mode.

Description

Type

Color

Meaning

PRT1

RS232

Green

Flashes to indicate communication

PRT2

RS422

Green

Flashes to indicate communication

TX

Mechatrolink

Green

Flashes to indicate communication

RX

Mechatrolink

Green

Flashes to indicate communication