beautypg.com

Wiring - three phase, Figure 2.9: three-phase wiring – Yaskawa MP940 Hardware Manual User Manual

Page 16

background image

MotionSuite™ MP940 Machine Controller Hardware Manual

Section 2: Startup

13

Wiring - Three Phase

Apply power to the SGDH and MP940 simultaneously. If the SGDH is not powered
within 10 seconds after turning power ON to the MP940 (or vice versa), the units will
not communicate with each other. Note: For maximum noise immunity, connect the
FG to a ground terminal on the sub-panel, or to the ground terminal on the SGDH.

R

Control
Power

ON

Control
Power

OFF

1MC

Servo

Power

ON

Servo

Power

OFF

2MC

Emergency

Stop

1MC

1MC

SUP

2MC

SUP

1MCCB

T

S

2MC

1MC

24VDC

Supply

+24V

0V

+24V

BAT

RDY
RUN
ALM

BAT
PRT1

6
5
4
3
2
1

NO

PRT2

RUN
INIT

TEST

FLASH
PP
COPY

PORT1

PORT2

POWER

+24V

GND
FG

LED

I/O

TX

R
X

1

2

M
E
C
H
A
T
R
O
L

I

N
K

MP940

L1
L2

L1C

B1

L2C

B2

L3

Noise Filter

Figure 2.9: Three-phase Wiring