Section 3: DIP Switch Definition

18

„

Copying Servo Amplifier Pn Data from MP940 to SGDH

It is possible to load parameter data that was downloaded to the controller via
MotionWorks or MotionWorks+ by turning off all DIP switches except the copy
switch. The parameter transfer will occur at power up. The display panel on the SGDH
will go off during the parameter transfer. Return the DIP switches to standard
operation and cycle power after the operation is complete.