PL.F7.05 Page
7
of 54
GPD506/P5 to F7 Specification Differences
Feature
or Function
Item
Yaskawa GPD506/P5
Yaskawa F7
Performance Features
240V
0.75 to 125HP (VT)
0.5 to 150HP (ND)
1
480V
0.75 to 500HP (VT)
0.5 to 500HP (ND or HD)
1
HP Range
Note: The voltage rating in
the “Item” column is
generalized. Refer to the
Service Conditions section for
rated input voltage
requirements.
600V
2 to 200HP (VT)
Available w/GPD506/P5
Not Available in F7
Overload Rating
% for Minutes
150% for 1 min (CT)
200% peak
120% for 1 min (VT)
180% peak
150% for 1 min (HD)
110% for 1 min (ND)
200% peak
PWM Carrier Frequency
Range
See Carrier Frequency Table
See Carrier Frequency Table
Max. Output Frequency
Hz 400Hz
300 Hz (HD) 400 Hz (ND)
1000 Hz optional
V/f 40:1
40:1
V/f w/PG
Not Applicable
50:1
Open Loop
Not Applicable
200:1
Speed Range
Closed Loop
Not Applicable
1000:1
V/f w/PG
Not Applicable
0.2%
Open Loop
Not Applicable
0.2%
Speed Regulation
Closed Loop
Not Applicable
0.01%
Starting Torque at Low Speed
% @ Hz
100% @ 3Hz (V/f)
150% @ 1.0Hz (V/f)
150% @ 0.5Hz (OLV)
150% @ 0.3Hz (Closed loop)
Protective Features
Torque Limit / Current Limit
Stall Prevention
-
-- Stall Prevention During
Accel/Run/Decel (V/F)
-- Undertorque Warning and
Output Action
-- Torque Limit Accel/Run/Decel
Stall Prevention During
Accel/Run/Decel (V/F)
Torque Limit in 4 Quadrants
(OLV)
Over/Under Torque Detection
Heat Sink Temperature Fault
Fault Action
Coast, Ramp, Continue
Coast, Ramp, Continue or
Continue with reduced speed
Design Features
Display
2 Line x 16 Character LCD
5x7 Segment LED (Optional)
5 Line x 16 Character LCD (Std)
5x7 Segment LED (Optional)
Qty of keys
7
11
Language 1
7
(w/LCD)
Keypad Design
Copy Function
No
Yes
1