Product Transition Guide
Purpose

PL.F7.05 Page

6

of 54

F7 Benefits vs. P5

(continued)

F7 Functional Improvements

(continued)

10 additional preset speeds
for a total of 16 preset
speeds plus jog

Three jump frequencies

Selectable Torque/Speed
control

Motor 1 and Motor 2
parameter sets for switching
between two different
motors on one drive

Over-speed detection in
torque control for safe
operation

Speed deviation and encoder loss detection circuits and
software

Independently adjustable accel and decel S-curve
profiles

Two new PID operating modes:
(Freq. Ref. + PID output (D =Feedback)
( Freq. Ref. + PID output (D = Feed-Forward)

Set a predefined speed to run at when serial
communication is lost.

Modbus serial communication speed is now faster at
19200 baud.


F7 I/O Improvements

Two more digital inputs for a total of eight

Two additional relay outputs M5 and M6 relays

One more analog input than P5 for a total of 3 analog
inputs

A convenient PCB switch now changes analog input
A2 between current and voltage, cutting PCB jumper
for mA signal is no longer required

Analog output monitors are now programmable to:
0-10V, -10 to +10v, 4-20ma signal levels

22 more programmable functions for digital inputs than
P5. 51 total

35 possible programmable functions for the digital
outputs, 18 more than the P5

24 programmable selections for the analog outputs, 20
more than the P5

More versatile PNP/NPN sinking/sourcing I/O

Optional high resolution 14 bit analog input card



F7 I/O Improvements

(continued)

Optional 8 channel or 16 channel binary/BCD digital
input cards

Optional 12 bit analog output card

Option expanded 2 channel or 8 channel digital output
card

Built-in RS-485/422 modbus serial communications

Adjustable analog input signal filter for added stability

Additional pulse train input and output signals

Motor thermister input with overheat alarms and fault
signals


F7 Start-up, Installation & Maintenance
Improvements

Enhanced digital keypad
( 5 Line x 16 Character LCD (Std)

Parameter copy function to another F7 using standard
digital operator

Improved fault storage, last 10 faults

Quick disconnect I/O blocks for easy wiring

Six more keypad language selections

User customizable parameter list displays (A1-02)

Two independent programmable over and under torque
detection levels

Automatic ambient temperature compensation to
protect the drive in environments exceeding its rating

Logged cooling fan hours for scheduled maintenance

Modular cooling fan for easy replacement

Automatic cooling fan run control to extend fan life

15 different preset V/f patterns for easy V/f profile set-
up