beautypg.com

Appendix 3- parameter cross reference, Parameter name – Yaskawa GPD 506/P5 to F7 User Manual

Page 40

background image

Appendix 3- Parameter Cross Reference

PL.F7.05 Page

40

of 54

GPD506/P5 Parameter

F7 Parameter

Param

No.

Nxxx

Parameter

Name

Description or Selection

Description or Selection

Parameter

Name

Param.

No.




(con’t)

037



















































Multi-function
contact input 2
(terminal S3)





































































Set range: 2-28
































































5: Multi-Step Frequency Reference 3
6: Jog Frequency Reference
Closed = frequency reference from d1-17
7: Accel/Decel Time Se1ection 1
8: External BaseBlock N.O.
Closed = Output transistors forced off.
Open = Normal operation.
9: External BaseBlock N.C.
Closed = Normal operation.
Open = Output transistors forced off.
A: Acc/Dec Ramp Hold
Closed = Acceleration suspended and
speed held.
B: External Overheat Alarm (OH2)
Closed = OH2 alarm.
C: Terminal A2 Enable
Closed = Terminal A2 is active.
Open = Terminal A2 is disabled.
D: V/F Control with PG Disabled
Closed = Speed feedback control
disabled.
E: ASR Integral Reset Closed = Integral
reset.
F: Terminal Not Used Terminal closure has
no effect.
10: MOP Increase
Closed = frequency reference increases.
Open = frequency reference held.
Must be set in conjunction with MOP
Decrease and b1-01 must be set to 1.
11: MOP Decrease
Closed = frequency reference
decreases.
Open = frequency reference held.
Must be set in conjunction with MOP
Increase and b1-01 must be set to 1.
12: Forward Jog
Closed = Drive runs forward at
Frequency reference entered into
parameter d1-17.
13: Reverse Jog
Closed = Drive runs in reverse at
frequency reference entered into
parameter d1-17.
14: Fault Reset
Closed = Resets the Drive after the fault
and the run command have been
removed.
15: Fast-Stop N.O.
Closed = Drive decelerates using
C1-09,
regardless of run command status.
16: Motor 2 Selection
Closed = Motor 2 (E3-, E4-oo)
Open = Motor 1 (A1-02, E1-oo, E2-oo)
17: Fast-Stop N.C.
Closed = Normal operation
Open = Drive decelerates using C1-09,
regardless of run command status.
18: Timer Function
Input for independent timer, controlled
by b4-01 and b4-02. Used in
conjunction with the multi-function
digital output function
H2-oo = 12 “timer output”.
19: PID Disable
Closed = Turns off the PID controller.
1A: Accel / Decel Time Selection 2
Based on status of Accel/Decel Time
Selection 1 and 2.
1B: Program Lockout
Closed = All parameter settings can be
changed.









Multi-Function Digital Input
Terminal S3 Function
Selection

































































H1-01