Appendix 3- Parameter Cross Reference
PL.F7.05 Page
45
of 54
GPD506/P5 Parameter
F7 Parameter
Param
No.
Nxxx
Parameter
Name
Description or Selection
Description or Selection
Parameter
Name
Param.
No.
041
contact output 1
(terminal MA-MB-MC)
(when in torque control)
Closed = When motor frequency is at
the speed limit value when running in
torque control.
33: Zero-Servo Complete
Closed = When Zero Servo is complete
within the b9-02 zero servo completion
width.
37: During Operation
Closed = When Drive is operating
(except during baseblock or DC
braking).
38: Drive Enable
Closed = When the Drive enable input
is active.
Terminal M1-M2 Function
Selection
H2-01
042
Multi-function
contact output 2
(terminal M1-M2)
It is the same as constant n041.
Same selections as H2-01
Terminal M3-M4 Function
Selection
H2-02
043
Analog input select
Note: (n084 ≠ 0) FV term = master speed, FI terminal = feedback. Memobus
register 80H=0 does not set 3 & 4.
-
044
Terminal FI signal Level
Selection
0: The FI terminal inputs 0-10V.
(Jumper J1 is cut)
1: The FI terminal inputs 4-20mA.
Selects the signal level of terminal A2.
0: 0 to 10Vdc (switch S1-2 must be in the
OFF position).
1: -10 to +10Vdc (switch S1-2 must be in
the OFF position).
2: 4 to 20mA (switch S1-2 must be in the
ON position)
Terminal A2 Signal Level
Selection
H3-08
045
Frequency Reference
Retention
1: The holding frequency reference is not
memorized.
0: The holding frequency reference is
memorized and stored in n024
This parameter is used to retain the held
frequency reference in U1-01 (d1-01) when
power is removed. This function is
available when the multi-function inputs
“accel/decel ramp hold” or “up/down”
commands are selected
(H1-XX = A or 10 and 11).
0: Disabled
1: Enabled
Frequency Reference Hold
Function Selection
d4-01
046
Frequency Ref
Loss selection
0: No detection
1: Continue running at n047 setting
The frequency reference is considered lost
when reference drops 90% or more of its
current value in less than 400ms.
0: Normal Operation - Drive will run at the
frequency reference.
1: Run at L4-06 PrevRef - Drive will run at
the percentage set in L4-06 of the
frequency reference level at the time
frequency reference was lost.
Frequency Reference Loss
Detection Selection
L4-05
047
Frequency Ref
when frequency reference is
lost
Set unit: 1% and set range: 0-100%
0 to 100.0
If the frequency reference loss function is
enabled (L4-05=1) and frequency reference
is lost, the Drive will run at a reduced
frequency reference determined by the
following formula:
Fref=Fref at time of loss * L4-06.
Frequency Reference Level at
Loss Frequency
L4-06
048
Terminal FV gain
Set unit: 1% and set range: 0 to 200%
0.0 to1000.0
Sets the output level when 10V is input, as
a percentage of the maximum output
Terminal A1 Gain Setting
H3-02
Value Terminal FV
FI terminal
Note
0
Master speed
Auxiliary
FV/FI switch enabled
1
Auxiliary
Master speed
FV/FI switch enable
2
Fault reset
Master speed
FV/FI switch disabled
3
Master speed
N
monitor
input
FV/FI switch disabled
4
Fault reset
N
monitor input
FV/FI switch disabled