beautypg.com

Function block setup - quick reference, 1 sources, 2 operations – Yaskawa G5 Eliminator User Manual

Page 3

background image

Date: 07/01/04, Rev: 04-07

Page 3 of 27

TM.G5SW.015

Function Block Setup - Quick Reference

Sheet 1 of 2

2.1 Sources

Connections

Figure

Description

Information

Input Output

Setup

Analog Input 13

Terminal 13

13

Terminal 13 can not be reassigned

Analog Input 14

Terminal 14

14

Terminal 14 – H3-09 = 20: Eliminator T-14

2.1.1

Analog

Inputs

Analog Input 16

Terminal 16

16

Terminal 16 – H3-05 = 21: Eliminator T-16

P2-02 = MOP Rate / second

MOP

25

P2-03 = MOP Max Percent
P2-04 = MOP Min Percent
P2-05 = MOP Rst Percent

2.1.2

MOP /

Step MOP

Step MOP

P2-06 = MOP Step Rate

26

H1-xx = 82: MOP UP
H1-xx = 83: MOP DOWN
H1-xx = 84: MOP RESET

P1-01

Range 0 to 65535

9A

P1-02

Range 0 to 65535

9B

P1-03

Range 0 to 65535

9C

P1-04

Range 0 to 65535

9D

2.1.3

Number

Inputs

P1-05

Range 0 to 65535

9E

PG Channel 1

F1-01 = Pulses Per Rev.

0E

PG Option Card Required (PG-X2 or PG-W2)

2.1.4

Pulse

Inputs

PG Channel 2

P2-01 = Pulses input at 100 %
inverter speed ( Range 0 to 65535)

OF

PG-W2 Option Card Required

2.1.5

10000

100 % Reference 10000 output value

12

2.1.6

0

0 % Reference

0 output value

18

2.1.7

Drive

Output

Output Reference

Percentage of Maximum Frequency
0-10000 output value

15

2.1.8

Torque

Output

Torque Reference

Percentage of 100.00 Percent Torque
0-40000 output value

11

2.1.9

Motor

Speed

Motor Speed
Percentage

Available in PG and Vector modes
only

17

Read Memory 1

46

Reads Write Memory1

2.1.A

Read

Memory

Read Memory 2

Reads the value written into memory
with the associated write memory.

47

Reads Write Memory 2


2.2 Operations

Connections

Figure

Description

Information

Input Output

Information / Equation

Input Value

30

Addition

Input Value to add

31

32

30 + 31 = 32

Input Value

3a

Subtraction

Input Value to subtract

3b

3c

3a - 3b = 3c

Input Value

50

Multiplication

Input Value to multiply by

51

52

(50 x 51) / 10000 = 52

Input Value

5a

Division

Input Value to divide by

5b

5c

(5a x 10000) / 5b = 5c

Absolute Value

Same Input / Output Connector

40

Absolute Value of X

2.2.1

Math

Change Sign

Same Input / Output Connector

41

X times -1