Yaskawa G5 Eliminator User Manual
Page 22

Date: 07/01/04, Rev: 04-07
Page 22 of 27
TM.G5SW.015
Parameter 3
P1-03 = 0
P1-03
Parameter
3
B B B B
This parameter is provided for user input. Refer to section 2.1.3.
Parameter 4
P1-04 = 0
P1-04
Parameter
4
B B B B
This parameter is provided for user input. Refer to section 2.1.3.
Parameter 5
P1-05 = 0
P1-05
Parameter
5
B B B B
This parameter is provided for user input. Refer to section 2.1.3.
Diam Filter Time
P1-06 = 0.1 sec
P1-06
Diameter Filter Time
B
B
B
B
The Diam Filter Time controls the rate of change within the winder filter. Refer to section 2.2.6.
Diam Bld Ratio
P1-07 = 0.1
P1-07
Diameter
Build
Ratio
B B B B
The Diam Build Ratio is the number equal to the ratio of core diameter to maximum roll
diameter. Refer to section 2.2.6.
Example:
Core
Diameter
=
4”
Max
Roll
Diameter
=
48”
Set
P1-07
=
48”
/
4”‘or
12
Setting Range:
0 to 65535
Factory Default:
0
Modify During Run:
Yes
Modbus Address:
0582H
Setting Range:
0 to 65535
Factory Default:
0
Modify During Run:
Yes
Modbus Address:
0583H
Setting Range:
0 to 65535
Factory Default:
0
Modify During Run:
Yes
Modbus Address:
0584H
Setting Range:
1 to 50 sec
Factory Default:
0.1 sec
Modify During Run:
No
Modbus Address:
0585H
Setting Range:
0.1 to 50
Factory Default:
0.1
Modify During Run:
No
Modbus Address:
0586H