6 related parameters – Yaskawa Option PG-F3 Motor Encoder Feedback User Manual
Page 33

6 Related Parameters
YASKAWA ELECTRIC TOBP C730600 51F 1000-Series Option PG-F3 Installation Manual
33
F1-06
(385)
PG 1 Ratio for
PG Pulse
Monitor
Sets the division ratio for PG encoder pulse output.
Set as a three-digit number: x is the first digit, y is the
second digit, and z is the third digit:
When using the PG-F3 option, the drive disregards
the value set for "x", and uses the formula 1/yz to
determine the division rate for the pulse generator.
The setting range is 1/32 : 1.
CLV
CLV/PM
Default: 1
Min: 1
Max: 132
F1-08
(387)
PG Overspeed
Level
Sets the level for detecting overspeed as a percentage
of the maximum output frequency.
CLV
CLV/PM
Default: 115
Min: 0
Max: 120
F1-09
(388)
Overspeed Det.
Time
Sets the time required for the motor to exceed the
level set in F1-08 to trigger a fault.
CLV
CLV/PM
Default: 0.0
Min: 0.0
Max: 2.0
F1-10
(389)
Excessive Speed
Deviation Det.
Level
Sets the degree of speed deviation to trigger a dEv
fault. Set as a percentage of the maximum output
frequency.
CLV
CLV/PM
Default: 10
Min: 0
Max: 50
F1-11
(38A)
Excessive Speed
Deviation Det.
Time
Sets the time required for a speed deviation situation
to trigger a fault.
CLV
CLV/PM
Default: 0.5
Min: 0.0
Max: 10.0
F1-14
(38D)
PG Disconnect
Det. Time
Sets the time in seconds for PG encoder disconnect to
be detected.
CLV
CLV/PM
Default: 2.0
Min: 0.0
Max: 10.0
F1-18
(3AD)
Reverse
Rotation Det.
for PG 1
0: Disabled
n: Number of times a dv3 situation must be detected
to trigger a fault.
CLV/PM
Default: 10
Min: 0
Max: 10
F1-19
(3AE)
Reverse
Rotation Det.
for PG 1
0: Disabled
n: Number of times a dv4 situation must be detected
to trigger a fault.
CLV/PM
Default: 128
Min: 0
Max: 5000
F1-20
(3B4)
PG 1 Hardware
Disconnect
0: Disabled. No fault if the connection is lost.
1: Enabled. Fault if connection is lost.
CLV
CLV/PM
Default: 1
Range: 0, 1
F1-50
(3D2)
Encoder
Selection
0: EnDat 2.1/2.2 Serial+Sin/Cos
1: EnDat 2.2 Serial only
2: HIPERFACE
CLV/PM
Default: 0
Range: 0 to 2
F1-51
(3D3)
PGoH Detection
Level
Sets the level for detecting a PG Hardware Fault
(PGoH). Set as a percentage of
.
CLV/PM
Default: 80
Min: 1
Max: 100
No.
(Addr. Hex)
Name
Description
Control
Mode
Values
Sin
θ
2
+ Cos
θ
2