10.1.2 Windy Boy 5000 / 6000 Operating

parameters

Unauthorized changes to the operating parameters may result in:

• Injury or accidents as a result of changing the internal safety

routines in the Windy Boy 5000 / 6000,

• Voiding of the Windy Boy 5000 / 6000 operating approval

certificate

• Voiding of the Windy Boy 5000 / 6000 warranty

Never change the parameters of your Windy Boy 5000 / 6000
without explicit authorization and instructions.

Name Unit

Value

range

(WB 5000 /
WB 6000)

Factory
settings
(WB 5000
/WB
6000)

Description

Betriebsart /
Operating
Mode

MPP
UKonst
Stop
Turbine Mode
Insel Mode

Turbine

Operating mode of the Windy Boy
5000 / 6000:
MPP: Maximum Power Point
UKonst: Constant voltage mode
(Desired voltage is defined in "Usoll-
Konst")
Stopp: Disconnection from mains
supply, no operation
Turbine: Operating mode for wind
turbines, the input voltage is converted
according to the V/I function defined by
U

PV

Start, U

DC

WindStart and

U

DC

WindMax.

Default

GER/ENS

Used for setting the country specific
information.

dFac-MAX

Hz/s

0.005 ... 4,0

0,25

Maximum "Mains frequency change"
before the mains monitoring system
disconnects the device from the mains
supply.

dZac-MAX

mOhm

0 ... 20000

350

Maximum "Mains impedance change"
before the mains monitoring system
disconnects the device from the mains
supply.

E_Total

kWh

0 ... 200000

Total energy yield (E_Total) and total
hours of operation (h_Total) for the
Windy Boy. This change may be
necessary when you exchange your
Windy Boy 5000 / 6000 and want to
use the data from the old device.

h_Total

h

0 ... 200000

Fac-delta-

Hz

0

...

4,5

0,19

Maximum frequency, above (Fac-
Delta+) and below (Fac-Delta-) the
mains frequency of 50 Hz, before the
mains monitoring system disconnects the
device from the mains supply.

Fac-delta+

Hz

0 ... 4,5

0,19