Operating instructions
Display message during operation
The display shows the most important operational information of the Windy Boy
5000 / 6000 in a continuous cycle. The following three diagrams serve to clarify the
messages. Every message is displayed for 5 seconds. Then the cycle begins again
.
The energy generated today and the current
operational status are first displayed.
Subsequently, the current feed-in power and the
output voltage are displayed.
This is then followed by the total energy produced so
far and the operational hours of the device.
Fault displays
If an operational fault develops, the display
immediately switches to "Disturbance" and the
background illumination is switched on.
The cause of the fault is displayed for 5 seconds in
the second line of the display.
If a measured value is responsible for the fault
condition, then the value measured at the time of the
fault is displayed. If another measurement is
possible, the current value is displayed in the second
line.
After another 5 seconds, normal operational information is again displayed.
If the fault is still present, the fault display starts again from the beginning. An
overview of the status and fault messages can be found in chapter 10.2 "Fault
messages” (page 60) of this document.
The amount of energy shown under "E-today" does not necessarily reflect the
amount of energy produced over the last 24 hours. This is rather the energy
produced by the Windy Boy 5000 / 6000 since the last deactivation/
activation.
Energy sum since the last activation, and
the current operational status
E-today 3.86
Status Turbine
Current feed-in power and
AC voltage
Pac 903W
Vac 195V
Total amount of energy produced and the
total number of operating hours
E-total 724.4kWh
h-total 512h
Fault display
Disturbance
Vac-Bfr
Display of the values measured
during the fault
at: 261V
present: 245V