6.4 General setting example
Please note that the following example only represents a starting point for operating
with a wind generator.
•
This achieves an early switch-on of the Windy Boy 5000 / 6000.
•
This achieves an early mains supply feed-in. If the wind turbine does not properly
start, or the Windy Boy frequently switches on and off, it is recommended that you
increase
•
of the Windy Boy 5000 / 6000:
In this case the slope of the ramp function is relatively flat. The maximum output
power is only reached with a relatively high DC input voltage, which avoids
"braking" of the wind generator through excessive power consumption. This
setting is especially suitable in locations with little or weak wind. Once the
properties of the wind generator are known, then the reduction of the
power from the wind generator even at low DC input voltages (low wind speeds).
The ramp function will then be steeper.
•
Here, the Windy Boy remains connected to the mains supply, even at low DC
input voltage levels, and "waits" for the next gust of wind. This delays an early
switch-off of the Windy Boy.
•
This achieves a reduction of the switch-on time (please observe the regulations of
the energy supplier responsible).
Contact the manufacturer of your wind generator for the typical properties of
your generator (voltage/power characteristic).
Only change the operating parameters when you know exactly what you are
doing!