3 general data, General data – SMA WB 5000 User Manual
Page 51
SMA
Technology AG
Technical data
Operating instructions
WB50_60-11:FE4105
Page 51
9.1.3 General data
For a detailed description of the device, see chapter 3 "Unit description” (page 13)
of this manual.
The efficiency of the Windy Boy 5000 / 6000 is heavily dependent on the DC input
voltage.
General data
Protection category per DIN EN
60529
IP54
External temperature range
-25° C to +60° C
Dimensions (w x h x d)
430 mm x 600 mm x 450 mm
Weight
63 kg (approx.)
External interfaces
Data transfer (mains cable)
Optional
Data transfer (data cable)
optional, RS232 / RS485, electrically
separated
Data transfer (wireless)
Optional
Efficiency
Max. efficiency
η
max
> 95,6 %
Ov
er
all Ef
ficiency [%]
Output Power [W]
96
95
90
91
1000
92
93
94
0
2000
3000
4000
5000
6000
500 V
400 V
300 V
250 V
Windy Boy 5000