2 windy boy 6000, 1 dc connection data, Windy boy 6000 – SMA WB 5000 User Manual
Page 52: Dc connection data

Technical data
SMA
Technology AG
Page 52
WB50_60-11:FE4105
Operating instructions
9.2 Windy Boy 6000
9.2.1 DC connection data
Max. input open circuit voltage
U
DC 0
600 V
Input voltage, MPP range
U
DC
246 V ... 600 V DC
Nominal DC operating voltage
U
DC nom
270 V
Max. input current
I
DC max
26.0 A
Max. input power
DC
max
6300 W
Recommended generator power
at 5,000 full-load hours / year
P
turb max
4400 W
Recommended generator power
at 2500 full-load hours / year
P
turb max
4950 W
All-pole isolator on
the DC input side
DC plug connector
Overvoltage protection
Thermally monitored varistors
Voltage ripple
U
PP
< 10% of the input voltage
Personal protection
Insulation monitoring (Riso > 1 MΩ)
Own consumption in standby
mode
< 7 W
Reverse polarity protection
Short circuit diode
This manual is related to the following products: